Collection List: 0 Products   » Show Collection List «

Do you have questions about our products or services?

Just give us a call:
+49 (0) 6874 / 18 22 77

Or send your inquiry via e-mail:
info@holbach.biz

Umweltanalytik Holbach GmbH

Technical guide

Legacy Chemical Surveys

  • MBASS30V3 with transverse adapter and polyurethane foam cylinder

An investigation of an older building may start with treated timber, an old joint sealant or an unfamiliar coating. Those observations help frame a sampling question. The laboratory’s list of target substances and its validated method determine whether sampling indoor air on polyurethane foam is suitable.

At a glance

Application Selecting a transverse adapter for indoor air investigations of legacy chemicals
Equipment MBASS30V3, transverse adapter and laboratory-specified media
Laboratory assessment Target compound analysis

Start with the suspected source

Record the material, building history and intended use of the room. Agree whether the question concerns a suspected material source, airborne exposure or change after works. Air and material samples can answer different parts of the investigation. The laboratory should advise which evidence the commission requires.

Specify the adapter and media together

The transverse adapter provides a holder for polyurethane foam when used in the chemical sampling configuration. Where particles must also be retained, discuss the FH50 filter holder and the filter required by the method. The inlet nozzles used with the transverse adapter for ventilation duct surveys serve a different sampling application.

Check suitability for the decision

Before fieldwork, ask whether the method covers the named wood preservatives, biocides, flame retardants or PCB congeners at the reporting limit required. Obtain instructions for media preparation, blanks and transport. A longer sample cannot by itself correct an unsuitable medium or an inappropriate analytical method.

What if a laboratory method calls for a different sorbent?

Send the method to Holbach with the required media dimensions and your instrument model. Compatibility and the achievable sampling conditions can then be reviewed before an accessory is selected.

Configure the transverse adapter for legacy chemical investigations. Tell us the suspected substances, specified collection medium and required reporting limit.

Sources and equipment

Transverse adapter · Transverse adapter data sheet · Holbach technical documents