Technical guide

Mould Survey Results

  • MBASS30V3 with PS 30 particle sampling head

After mould remediation, agree what the survey is intended to demonstrate before choosing the sample. A microscopic spore count can complement the visual inspection and the assessment of moisture damage. The PS 30 collects particles on coated slides for laboratory examination.

At a glance

Application Air sampling after mould remediation: interpreting a total spore count
Equipment MBASS30V3, PS 30, coated slides
Laboratory assessment Microscopy assessed with inspection findings

Define what completion means

A contractor, an independent surveyor and a client may need different evidence. Record what was removed or cleaned, what remains accessible for inspection and how the result will be assessed. The German WTA guidance sheet 4-12 is relevant where the project specifies it. Its use and the acceptance criteria belong in the survey brief.

Make comparisons interpretable

Document the inspected area, sampling locations, timing relative to cleaning and the ventilation state. Conditions during the survey influence which particles are present in air. Ask the laboratory how it wants reference and investigation samples identified so that each result can be traced back to the site record.

Interpret the count with the inspection findings

Microscopy can include spores that will no longer grow in culture. A count is a snapshot of the sampled air. A low count alone cannot resolve a concealed moisture problem or establish that every surface is clean. Discuss an unexpected result with the analyst and inspect the relevant area before drawing conclusions about the work.

What should I send with the slide?

Provide the sample identifier, sampled volume, location, date, comparison sample and survey question. Agree the reporting format with the laboratory in advance.

Select equipment for a post-remediation mould survey. Tell us the stage of the works, the agreed inspection objective and your existing equipment.

Sources and equipment

PS 30 · WTA guidance sheet 4-12 · Holbach technical documents